12
CHAPTER 4: TROUBLESHOOTING
4.1 Console Error Codes
Error Messages on the Console
Code Class Description Solution
0x0441 B
When UCB implements a command, LCB has not
received this command.
Check the console cable connection, replace the LCB.
0x01AC C
Power resistor is short circuited (over 4A), or the current
is over 3.7A for 1 second.
Check the connection of power resistor or replace power resistor
0x02AB C Machine Type Error Set the Machine Type to the correct type of LCB
0x02B3 C Resistance Type Error Set the Machine Type to the correct type of LCB
0x04A0 C
The LCB has no message returned to the UCB for ove
3 seconds.
Check the console cable connections, replace the LCB / UCB as needed.
0x0201 A LCB Battery Low Voltage Check battery recharge function or replace new battery
0x0248 B Battery disconnection or fail. Check the connection of battery or replace new battery