CHAPTER 5: PART REPLACEMENT GUIDE
5.20 Testing the Bike
ONCE THE UNIT OR REPLACEMENT PART IS FULLY INSTALLED AND ASSEMBLED AND
PROPERLY PLACED ON THE FLOOR, USE THE FOLLOWING INSTRUCTIONS TO SETUP AND
TEST THE MACHINE:
1) Check that the console is set for bike.
a. Press & Hold both UP and DOWN RESISTANCE keys until Engineering Mode appears on the display.
b. Use the UP or DOWN RESISTANCE keys to scroll to Machine Type.
c. Press GO on Machine Type and make sure it is set for Bike.
d. If Machine Type is not set for Bike, change to Bike using the UP or DOWN RESISTANCE keys and press STOP to save.
e. Press and hold the STOP key for 3-5 seconds to return to normal function.
2) Without hitting start or entering any program modes, sit on the bike and hold the handlebars while pedaling to simulate exercising. While moving, listen
for any odd noises or squeaks.
3) After stopping movement, press the green GO key and begin pedaling.
4) Grasp the hand grips to check for proper heart rate response.
5) Press the level up and down buttons on the console and hand grips to make sure resistance is fully functional.
6) If everything functions properly, stop pedaling and the unit will reset to normal operation within 30 seconds.